PCFC-Entity (Business Unit) Name: Trakhees - Ports, Customs & Free Zone Corporation
Department Name: Civil Engineering Department (CED)
Section Name: Permits Section (Facilities)
Document Reference Number: PCFC-TRK-CED-PS-REG-06
Revision Number: 01
Revision Date: May 2019
Classification: Public
6.1 Separate entry and exit gate to be provided for heavy and light motor vehicles at the Industrial / Warehouse facility.
6.2 Setback area of minimum 5.5 meters inside all around the boundary/fence line in all industrial /warehouse buildings / facilities and 3 meters setback area in all residential development shall be kept to provide fire breaks (To maintain segregation of fire from other facilities) and meet/handle other emergency situations.
6.3 Unimpeded road for emergency access not less than 5.5 meters wide around the Industrial / Warehouse buildings and facilities in Free Zone area shall be provided.
6.4 Roads shall be of sufficient standard for use by fire tenders (any underground tank, manhole located on this road shall be of industrial purpose heavy duty) and shall be adequately illuminated. (Note: for other facilitie...