Unified UAE Legislation Database

Trakhees Regulations PS 34.0 Shafts & Ducts

Status

In force

Issuing Authority

Ports, Customs and Free Zone Corporation

Effective date

XX.XX.XXXX

Official Link

https://

PCFC- Entity (Business Unit) Name: Trakhees — Ports, Customs & Free Zone Corporation

Department Name: Civil Engineering Department (CED)

Section Name: Permits Section (Facilities)

Document Reference Number: PCFC-TRK-CED-PS-REG-34

Revision Number: 00

Revision Date: October 2010

Classification: Public

 

Regulation DD-34.O: Shafts & Ducts

The minimum area of the ducts and shafts for the natural lighting and ventilation requirements shall be as follows:

34.1 Bathrooms:

The minimum area of the shafts shall be 0.8 square meter and minimum width shall be 0.9 meter.

34.2 Closed Kitchens:

The minimum area of the shafts shall be 3 x 3 square meter, regardless of the buildings height and mechanical ventilation shall be provided, according to the specifications and conditions approved by the authority if the building exceeds ground floor plus 7 typical floors.

34.3 Open Kitchens:

It is permitted to build kitchens that occupy part of the common spaces (halls or living areas),with out providing ventilation shafts, regardless of the building height, as long as the kitchens are located opposite to the main ventilation openings of such common spaces, and ...