PCFC- Entity (Business Unit) Name: Trakhees — Ports, Customs & Free Zone Corporation
Department Name: Civil Engineering Department (CED)
Section Name: Permits Section (Facilities)
Document Reference: Number PCFC-TRK-CED-PS-REG-33
Revision Number: 00
Revision Date: October 2010
Classification: Public
33.1 A mess, pantry and Kitchen (where applicable) shall be constructed of fire resisting materials and comply with standards required by the Authority. However, note that the provision of kitchen/cooking is not permitted in the Industrial, Warehouse and Factory Building (including offices in the same buildings). Also Refer EHS - Food Establishment Guidelines.
33.2 Floors and walls shall be impervious to moisture and capable of being cleaned by washing down. Floors shall be hard-surfaced, non-absorbent & adequately drained. They shall be constructed with waterproof, non-absorbent washable materials without fissures or crevices.
33.3 Walls shall be tiled to a height of 2.1m above floor level with glazed ceramic tiles and Floor with unglazed ceramic tiles. Internal walls shall be smooth, waterproof...