4.1. Scope

This Section addresses broadly the major Occupational Health & Safety aspects of industrial operations that need to be adhered to by companies/ establishments during their operations in Trakhees jurisdictional areas.

 

4.2. Protection of Employees

Employers must provide adequate & appropriate proactive and preventive measures for protection of their employees from risk of injury or occupational disease, fire risks or other kinds of risks which may result from occupational hazards such as the use of machinery and other equipment, handling of chemicals/ toxic substances or performing any other task at the workplace. Prior to engaging them in work activities employees must be informed of their roles, responsibilities, risk out of the activities they will perform and how to overcome these occupational risks.

 

4.3. Duties of Employees

All employees must:

4.3.1. Follow correct procedure, don’t take chances, if you don’t know, ask.

4.3.2. Correct / Report unsafe conditions and help to keep everything clean and orderly.

4.3.3. Use right tools and equipment for the job, use them safely.

4.3.4. Report all injuries, get first aid promptly.

4.3.5. Use, adjust and repair equipment only when authorized and competent to do so.

4.3.6. Use appropriate equipment, wear required personal protective equipment, and keep them in good condition.

4.3.7. Don’t horseplay, avoid distracting others.

4.3.8. Follow correct manual material handling practices.

4.3.9. Follow instructions and signs posted for the protection of employees from occupational hazards

 

4.4. Safe Working Conditions

The employer and occupier of any workplace/industry/factory/construction site has a responsibility to provide safe working conditions/environment, Safety Gears/ Personal Protective Equipment for all employees and take necessary actions to prevent incidents and accidents at the workplace.

 

4.4.1. Risk Assessment and Communication:

In relation to the above the employer shall carry out suitable and sufficient hazard analysis and risk assessment to identify all related potential risk out of his organizational activities which might lead to certain kind of harm in terms of injury to person or damage to the environment. Suitable and sufficient preventive control measures need to be identified by the employer / his representative to prevent such incidents / accidents.

 

These occupational risk assessments and applicable preventive / reactive control measures shall be communicated to all relevant employees thru adequate internal / external trainings to make the employees adequately aware of existing occupational risks pertaining to their work activities and how to overcome them practically at workstations. Records of internal / external trainings shall be maintained.

 

4.5. Safety Policy

The employer/ occupier of any workplace employing over 100 staff and/or carrying out activities with potential risks shall prepare a suitable & sufficient occupational health and Safety policy and HS&E manual to the satisfaction of the Competent Department which shall be communicated to employees and shall post this manual/policy in prominent locations at the workplace in languages generally understandable by the workers.

 

The Occupational manual should address the following elements but not Limited to or adequate to

- OHS Policies and strategic objectives

- OHS Organization chart and their roles and responsibilities

- Hazard Analysis

- Legal requirements and compliance

- Incident reporting and Investigation

- Onsite / Off site Emergency management procedures

- Risk evaluation and management procedures

- Implementation, Monitoring and Reporting

- Inspection management and Audits

- Management of non-conformances and corrective actions

- Management review, Communication and Further Improvements

 

4.6. Safety Management

Depending on the needs or any changes in regulation and standard requirements issued by Local & Federal Authorities or International Bodies (as applicable) Trakhees – EHS Department may formulate, adopt and/or modify relevant guidelines and suitable codes of practice (not included in this document) or Issue additional guidelines to ensure the protection of the Health & Safety of the workers. Employer shall refer to such changes / amendment in regulation and shall update his organizational OHS management system in order to comply with all latest applicable regulatory requirements.

 

4.7. Competency and Training

Lessees or their representatives must initially ensure that the employee(s) are qualified, trained, licensed (where applicable) and competent in the nature of work, and brief their employees before starting work of the risks and dangers involved in the profession they are engaging in, such as but not limited to fire, risk out of machinery, risk from hazardous vapour or dust of toxic substances, danger of falling and relevant occupational diseases etc. Suitable training should be given to all staff involved in any potentially dangerous/hazardous operation/activity and such training shall be ongoing/ periodic.

 

4.8. Occupational H&S Precautions

Particular attention should be given to the following at the place of work.

 

4.8.1. The floor of the workplace must have an even surface and be trip free.

 

4.8.2. Sufficient space must be provided around machinery (Minimum 1 meter from extendable machinery parts) and between machinery/storage and walls, giving the workers room to move and carry out their ordinary duties without obstacle, and allowing for repair of their machinery and the transfer of items used at work.

 

4.8.3. Passages are to be free from goods, holes, uncovered manholes, projecting nails, pipes, cables etc. or other installation, which could cause a hazard.

 

4.8.4. Fire (emergency) exits/access, fire equipment and/or electrical panels/installations should not be obstructed by any means.

 

4.8.5. Preventive/Corrective measures should be taken in areas/activities with potential occupational health risks. This could include (but not limit itself to), indoor air quality monitoring, noise monitoring, staff medical evaluations etc.

 

4.9. Indoor Air Quality - Occupational Health - Exposure Standards

For the maximum indoor concentration levels of gas, fumes, vapour or dust at any industrial operation, refer Tables 2 & 2A - Appendix.

 

4.9.1. Purpose: 

A purpose for establishing acceptable concentrations is to provide a basis for interpretations of the results of air analysis as an indication of the severity of potential exposure. Comparison of air analysis results with acceptable concentrations indicates acceptable conditions or otherwise need, extent & urgency of control measures.

 

4.9.2. Sampling and analysis shall be performed by Trakhees/ DM registered third party laboratories to provide an independent reliable indication of potential exposure.

 

4.9.3. The “Acceptable concentrations” are the highest allowable concentration in the normal working atmosphere.

 

4.9.4. Employer/Lessee shall hold responsibility to maintain the required concentration levels as specified.

 

4.9.5 The Competent Department may require the Employer/Lessee to undertake studies by an approved Laboratory periodically to ensure compliance with Regulations.

 

4.9.6 An occupier in control of any workplace covered by a code of practice or handling any substance, for which an exposure standard is specified, shall comply with the technical and management directions stated therein.

 

4.10. Medical Examinations – Occupational Health Card

The employer shall arrange for a medical examination through TRAKHEES of all workers engaged in Processing / manufacturing activities (See Article 5) that are hazardous and/or pose a potential risk to the health of workers at the expense of the employer every 12 months and maintain a record of these results. All medical examinations carried out for this purpose shall be conducted at the clinic or hospital endorsed by Competent Department. It remains the employer’s responsibility to assess such potential health impacts and take all suitable measures and record workers’ health parameters during the period of employment and ensure that any identified problem is addressed immediately.

 

4.11. Enforcement of Medical Examination Requirement

The Competent Department may at any time, direct any employer or occupier to conduct a medical examination of workers under his control, at a nominated government clinic or hospital, if, in the opinion of the Competent Department, their health may be at risk. The employer shall ensure that any medical evaluation described in is relevant to the nature of the risks of the job as advised by the Competent Department.

 

4.12. Warning Signs

Lessees must provide warning signs in all potentially dangerous areas, such as chemical/ gas cylinder storage areas, machinery, drills etc. Lessees must provide safety signs for protective clothing as per working hazard, such as “WEAR SAFETY GEAR” for noisy areas, “WEAR MASK” for dusty operational areas, in addition to other signs like “NO SMOKING”, FLAMMABLE STORAGE AREA” etc.

 

4.13. Housekeeping

Proper housekeeping and stacking of materials within the buildings/warehouses must be practiced. Areas outside pre-built warehouses, corridors between offices of leased buildings, open areas between plots of land and Authority property are not to be used for placement of equipment, materials, waste or other items. All such open storage grounds shall be hard surfaced and fenced/covered to maintain good aesthetics. Open areas within a lessee’s premises shall not be used for storage/dumping of any wastes/unused materials which either pose an HS&E problem or affect aesthetics.

 

4.14. Noise Exposure

Noise Exposure – The maximum continuous exposure level is 85 dB (A) for 40-hour working week. For levels above 85 dB (A) the allowable exposure duration is reduced. (Refer to Table 4-Appendix)

 

4.15. Electric Welding

4.15.1. A Work Permit should be issued by the Company/Lessee while carrying out any such works.

 

4.15.2. A welding helmet/ welding visor in good condition is to be used. Ultraviolet radiation from electric arc can cause “WELDERS” blindness and eye inflammation.

 

4.15.3. Gauntlet gloves of suitable type in good condition are to be used.

 

4.15.4. Radiation from electric welding can cause skin injuries and for this reason, the body must be properly covered. The use of overalls and aprons is recommended.

 

4.15.5. Ear protectors must be used by electric welders and gas torch operators while working in the overhead position or in other positions when welding bead can fall into the ear and cause severe injuries.

 

4.15.6. Protective goggles must be used when knocking up slag etc.

 

4.15.7. Live electrodes or electrode holders must always be placed in the correct holder when not in use.

 

4.15.8. Any welding arc is to be screened as much as possible to avoid other people being affected or exposed by the welding glare.

 

4.15.9. Welding equipment is to be checked for correct voltage, and the feed, earth and welding cables and electrode holders are to be free from defects. Defective cables and electrode holders are to be replaced.

 

4.15.10. Welding equipment is to be switched off when not in use.

 

4.15.11. The current is to be switched off when the welding cable is being pulled from one place to another.

 

4.15.12. Welding cable should not be laid on gas cylinders, oil containers or through wet areas etc.

 

4.15.13. It is forbidden to lay welding cables over hot steam boilers, steam pipes etc.

 

4.15.14. Welding cables are to be cleaned and coiled when welding work is finished.

 

4.15.15. Welding activity shall be carried out in fabrication shed. Proper ventilation and welding fumes extraction system for confined places and factory buildings should be provided as per Authority requirements.

 

4.15.16. When X-ray control is being carried out, this work is to be done by an expert and nobody is to stand behind the weld being examined or within a distance of at least 10 meters from the X-ray tube.

 

4.15.17. Precautions are to be taken to prevent adjacent objects from catching fire due to welding operations.

 

4.16. Gas Welding and Gas Installation

4.16.1. All gas cylinders should be treated carefully. Protective covers are to be fitted during storage and transport.

 

4.16.2. Gas cylinders must not be subjected to impact and must not be placed in intense sunshine or close to any object radiating heat or fire.

 

4.16.3. Gas cylinders are to be stored in shaded area, away from heat and ignition sources, placed upright and accessible from at least two sides.

 

4.16.4. Oxygen and other gas cylinders should not be kept together, considerable distances of about 6 meters to be maintained if possible.

 

4.16.5. Defective gas cylinders are to be marked “DEFECTIVE” and must be returned to the supplier as soon as possible.

 

4.16.6. Oxygen cylinders and oxygen equipment must not be placed in oily locations and handled with oily hands or gloves.

 

4.16.7. Valves on all gas cylinders must always be closed during pause in work, or on work completion. Valve covers are to be fitted when cylinders are not in use.

 

4.16.8. Acetylene gas hoses are to be red; oxygen hoses are to be blue.

 

4.16.9. Hoses and other equipment must not be hung on gas cylinders, values or other fixtures.

 

4.16.10. Gas hoses must not be laid over hot steam boilers or steam pipes etc.

 

4.16.11. Defective gas hoses must not be used. The only permissible way join to hoses is to use junction nipples.

 

4.16.12. Gas cylinders are to be fitted with Flame Arresters & Flash Back fire valves.

 

4.16.13. It is not permissible to use defective or damaged gauges on gas cylinders.

 

4.16.14. No welding/cutting work is to be carried out on/near oil/gas/chemical installations, pipelines, tanks, drums etc. Defective sections must be dismantled and taken to a safe place for repairing.

 

4.16.15. It is prohibited to manufacture acetylene gas by means of Calcium Carbide in a gas cylinder.

 

4.16.16. Fire extinguishing equipment must always be available during welding/cutting work.

 

4.16.17. Flammable/combustible substances/materials must be kept at a safe distance from a welding/cutting hot work area.

 

4.16.18. Approval from the Authority is required for transporting vehicle of gas cylinder/bulk gas to PCFC areas.

 

4.16.19. The design, construction and installation of bulk gas storage tanks should meet relevant international standards such as NFPA, API, ASME or any other relevant current standards and prior approval from Trakhees should be obtained.

 

4.16.20. Adequate work permit procedure (hot work, cold work permit) should be implemented by the company management prior to commencement of any hot and cold works.

 

4.16.21. Welding activity shall be carried out in fabrication shed. All welding areas shall be provided with suitable extraction/filtration systems to dissipate welding fumes.

 

4.16.22. All gas pipes/hoses are using inside the confined space shall be inspected at the beginning of each shift. Defective hose shall be removed from service also periodically leak tested and tagged to ensure the safe condition in order to prevent oxygen enrichment and explosion.

 

4.16.23. The use of pipes/hoses for conveying oxygen or flammable gases into a confined space should be controlled to minimize the risks.

 

4.16.24. All gas supply valves for pipes/hoses should be securely closed before the pipes and hoses are withdrawn from the confined space to a place that is well ventilated.

 

4.16.25. All Gas hoses cannot be removed inside the confined space, they should be disconnected from the gas supply at a point outside the confined space and their contents safely vented.

 

4.17. Ventilation

4.17.1. Adequate Local Ventilation (with filtration/mitigation arrangements where required) is to be arranged in connection with all types of works involving injurious or irritating gases/smoke/ fumes, which may occur or may form while the work is going on.

 

4.17.2. Ventilation is to start up before work commences; a check is to be made by Foreman/Safety Officer.

 

4.17.3. When welding and cutting work is being carried out in tanks and confined spaces, ventilation is to be arranged, preferably with both extraction and feed method with another person outside the tank as lifeguard.

 

4.17.4. Gases which form in connection with painting of tanks etc. are generally heavier than air and for this reason extraction is to be arranged in the bottom of the tank.

 

4.17.5. Spark free fan must be used while ventilating spaces where explosive gases occur.

 

4.17.6. The ventilation and air-conditioning of any facility should be designed based on ASHRAE Guidelines or any other relevant international standards. However, the ventilation for the hazardous chemicals storage and other critical areas should be re-evaluated by the Competent Department or the registered Risk Assessment Consultants.

 

4.17.7. Battery charging area shall be provided appropriate exhaust ventilation @ 8-10 air changes/hour.

 

4.18. Lighting

Employers shall provide adequate illumination in the workplace to ensure the safe conduct of work. Minimum illumination intensities should not be below those specified in Table 5 - Appendix. Further, lights and light fittings should avoid dazzle and glare and be so positioned that they do not cause hazards. Moreover, where persons are particularly exposed to danger, in the event of failure of artificial lighting, emergency lights must be provided.

 

4.19. Radioactive Works

4.19.1 Radioactive/Radiography work permit (on S3 Form) from Trakhees – EHS Department is required before carrying out radiography work involving radioactive materials.

 

4.19.2. For import/export of any radioactive sources, License from Federal Authority for Nuclear Regulation (FANR) website: www.fanr.gov.ae Email: [email protected] Tel: 02 6516666 shall be obtained by filling and submitting the relevant forms /details.

 

4.19.3. For Importing, Exporting, Storage and handling of radioactive isotopes in the PCFC- TRAKHEES jurisdictional areas, approval from the Authority is required. The current IAEA, local rules and regulations shall apply. For import of radioactive isotopes, S1 Form and for Export S2 Form should be filled...