GOVERNMENT OF DUBAI
Ports, Customs and Free Zone Corporation
PCFC-Entity (Business Unit) Name: Trakhees - Ports, Customs & Free Zone Corporation
Department Name: Civil Engineering Department (CED)
Section Name: Permit Section (Green Buildings/Sustainability)
Document Reference Number: PCFC-TRK-CED-GB-REG-02
Revision Number: 00
Revision Date: October 2010
Classification: Public
Systems that collect and absorb solar radiation, then transfer the solar heat directly to the interior space or to a storage system, from which the heat is distributed. There are two types of systems: liquid-based systems and air-based systems. If a system cannot provide adequate space heating, an auxiliary or back-up system provides the additional heat. Both air and liquid systems can supplement forced air systems.
A solar electric (photovoltaic or "PV") system, not passive solar design, that converts the sun's energy into electricity for the home. It is usually done with PV panels installed on the roof.
Air-sealing is the practice of filling gaps, holes, or cracks in a building's envelope in an effort to tighten the home's pressure boundary. Air sealing is one of the most significant energy efficiency improvements you can make to your home. Air sealing will not just reduce energy costs; it will also improve your home's comfort and durability. Some common air-sealing products include latex or silicone caulk, expanding foam products, weather-stripping, and even dense-packed cellulose in exterior walls.
A standard for residential mechanical ventilation systems established by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers. Among other requirements, the standard requires a home to have a mechanical ventilation system capable of ventilating at a rate of 1 cfm for every 100 square feet of occupiable space plus 7.5 cfm per occupant.
The tendency in ecosystems, when undisturbed, to have a great variety of species forming a complex web of interactions. Human population pressure and resource consumption tend to reduce biodiversity dangerously; diverse communities are less subject to catastrophic disruption.
A process that uses biological organisms to clean up contaminated water or soil; often used in oil-spill cleanup.
A landscape element, often a planted strip along a street or parking lot, for the purpose of capturing surface water runoff and filtering out silt and pollution before the storm water enters the drainage system or groundwater.
A diagnostic tool designed to measure the air tightness of buildings and to help locate air leakage sites. A blower door consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow. The combination of pressure and fan flow measurements is used to determine the building air tightness. The air tightness of a building is useful knowledge when trying to increase energy conservation or decrease indoor air pollution or control building pressures.
Abandoned or under-used industrial and commercial sites, sometimes characterized by environmental degradation and contamination, available for re-use.
The startup phase of a new or remodeled building. This phase includes testing and fine-tuning of the HVAC and other systems to assure proper functioning and adherence to design criteria. Commissioning also includes preparation of the system operation manuals and instruction of the building maintenance personnel.
The separation between the interior and exterior environment of a building. Usually consisting of the roof, doors, windows, foundation, and walls.
The air pressure within a building relative to the air pressure outside. Positive building pressurization is usually desirable to avoid infiltration of unconditioned and unfiltered air. Positive pressurization is maintained by providing adequate outdoor makeup air to the HVAC system to compensate for exhaust and leakage.
The most prevalent of the greenhouse gases. Emitted by burning fossil fuels. Naturally occurring from sources such as human and animal respiration, ocean-atmosphere exchange, and volcanic eruptions.
A tool to estimate a person's carbon emissions, based on how much energy and what kind of energy is used in daily activities. The result of the calculation is an estimated emission figure in terms of tons of CO2 that is a person's Carbon Footprint.
An individual's carbon footprint is the direct effect one's actions and lifestyle have on the environment in terms of carbon dioxide emissions. This is usually estimated by using a Carbon Calculator. From our home electricity use, to travel, to our diet, to the clothes we wear, all of our actions involve emission of carbon dioxide and have direct or indirect impact in accelerating climate change.
Also called climate destabilization or greenhouse effect, this term represents the adverse effects of greenhouse gasses on long term weather patterns.
Energy-efficiency measurement of heating, cooling, and refrigeration appliances. COP is the ratio of useful energy output (heating or cooling) to the amount of energy put in, e.g., a heat pump with a COP of 10 puts out 10 times more energy than it uses. A higher COP indicates a more efficient device. COP is equal to the energy efficiency ratio (EER) divided by 3.415.
A quality assurance process intended to confirm that all systems of a building-heat, air conditioning, electrical, plumbing, safety, security are operating as intended by the building owner and designed by the architect and engineer.
A process whereby biodegradable material (such as food waste or yard waste) is converted, in the presence of oxygen from the air, into a stable granular material which, applied to land, improves soil structure and enriches nutrient content.
Compact fluorescent light bulbs, which are more energy efficient than standard incandescent light bulbs and last longer.
Designing a building to take advantage of natural sunlight illumination.
A stream bed may be lost (dry up) if too much water is taken from it or the stream's course has been changed to divert it for other uses, such as irrigation.
The ratio of daylight illumination at a given point on a given plane, from an obstructed sky of assumed or known illuminance distribution, to the light received on a horizontal plane from an unobstructed hemisphere of this sky, expressed as a percentage. Direct sunlight is excluded for both values of illumination. The daylight factor is the sum of the sky component, the external reflected component, and the internal reflected component. The interior plane is usually a horizontal work plane. If the sky condition is the CIE standard overcast condition, then the DF will remain constant regardless of absolute exterior illuminance.
Unit of sound level or sound-pressure level. It is ten times the logarithm of the square of the sound pressure divided by the square of reference pressure, 20 micro Pascals.
Measure of how cold or warm a location is over a period of time relative to a base temperature, typically 65°F (although other base temperatures, such as 75°F, can be used for cooling). To calculate the number of heating degree-days (HDD) of a given day, average the maximum and minimum outdoor temperatures and subtract that from 65°F. The annual number of heating degree-days is a measure of the severity of the climate and is used to determine expected fuel use for heating. Cooling degree-days (CDD), which measure air conditioning requirements, are calculated by subtracting the average outdoor temperature
from an indoor base temperature.
A ventilation-control strategy in which the concentration of CO2 is the measured variable. This is controlled to a set point by modulating outdoor airflow. With this strategy, only human source contaminants are considered. CO2DCV will not comply with either procedure of ASHRAE Standard 62-1989.
The way the demand controller controls loads is called the load control strategy. It is the definition of each load's importance in relation to all other loads being controlled by the system. Generally, there are three load control strategies: priority (fixed), rotating or combination.
Double or triple pane glass windows often contain argon, krypton, or other gases between panes to reduce heat flow and improve insulation.
Species of plants, shrubs and vines which generally do not require additional watering in order to thrive in their native habitats. Landscapes with drought tolerant plants usually require little or no watering.
Toilets with two buttons for two flush options, one for liquid and another for solid waste. The button for liquid waste uses less water per flush.
A test that measures the air tightness of heating and cooling ducts.
Referred to as programmable thermostats. Programmable thermostats save energy by permitting occupants to set temperatures according to whether the house is occupied. These thermostats can automatically store and repeat settings daily with allowance for manual override. By eliminating manual setback, they allow the setting of more comfortable temperatures in the morning before occupants wake. Temperature setback can be adjusted for both heating and cooling seasons. Programmable thermostats can be set to adjust the temperature setting according to a user's schedule. These thermostats typically have a digital interface that allows more precise temperature control and a wider range of options or features.
A system created by the Kyoto Protocol, which allows countries that are under-target on emissions to swap spare emissions with over-target countries with the goal of limiting carbon emissions worldwide.
Embodied Energy is the total energy sequestered from a stock within the earth in order to produce a specific good or service including extraction, manufacture, and transportation to market. Energy that goes into making a product; includes energy required for growth, extraction, and transportation of the raw material as well as manufacture, packaging, and transportation of the finished product. Embodied energy is often used to measure ecological cost.
Amount of heat radiation emitted from a particular body or material. Emissivity is expressed in a fraction or ratio, with the lowest values indicating low emissivity and the highest indicating the high emissivity of flat black surfaces.
A written report prepared by a qualified party evaluating energy usage, highlighting weak points in energy efficiency, and identifying cost-savings measures. A less rigorous process than an energy audit.
A special inspection performed to determine where there are energy inefficiencies in a home or building. A qualified tester uses methods and measurements that comply with industry standards and involves collection of detailed data and an engineering analysis. A written report should include recommendations and a detailed cost and savings analysis.
Used to describe property or products that exhibit special features designed to save electrical and heat power for example, special light fixtures or double-insulated windows.
Products that use less energy than conventional models. The ENERGY STAR® label is a credible third-party certification of a product's energy efficiency. Consumers can also refer to the FTC's Energy Guide label, a yellow label affixed to most appliances today. Clothes washers, dishwashers, refrigerators, freezers, water heaters, window air conditioners, central air conditioners, furnaces, boilers, heat pumps, and pool heaters can get the label. Televisions, ranges, ovens, clothes dryers, humidifiers, and dehumidifiers do not receive such labels.
The fixture or the type of bulbs used in a fixture. Compact fluorescent lights (CFLs) and light emitting diodes (LEDs) are becoming more common in homes and buildings and they are more efficient and last longer than incandescent bulbs.
A type of ventilation system wherein the heated (or cooled) air being vented out of the home is used to heat (or cool) the supply air being pulled in from outdoors. The approach decreases the amount of energy needed to heat or cool the supply air.
The natural atmospheric processes of water entering the atmosphere after plants and soil have soaked up the moisture.
Any opening, or arrangement of openings, in a building (normally filled with glazing) that admits daylight and any devices in the immediate proximity of the opening that affect light distribution (such as baffles, louvers, draperies, overhangs, light shelves, jambs, sills, and other light-diffusing materials). Fiber optics. Design and construction of windows and doors.
Managing the amount, source, placement, form and timing of the application of nutrients and soil amendments so over application and loss of nutrients to surface and ground water does not occur.
Is a land area adjacent to a river, stream, lake, estuary, or other water body that is subject to flooding. This area, if left undisturbed, acts to store excess floodwater and dissipate the destructive energy of a flood.
A process used to remove VOCs from a building by operating the building's HVAC system at 100 percent outside air for a specific period of time.
The fine ash waste collected from the flue gases of coal combustion, smelting, or waste incineration.
A gas used widely in production of adhesives, plastics, preservatives, and fabric treatments and commonly emitted by indoor materials that are made with its compounds. It is highly irritating if inhaled and is now listed as a probable human carcinogen.
A mechanical ventilation component of the HVAC system that draws in fresh air rather than recirculation and filtering air within a home.
Is a renewable technology. Obtaining heat from underground hot water or, more commonly, employing a heat pump to warm or cool air by utilizing the constant temperature of the earth.
When referring to windows or doors, the transparent or translucent layer that transmits light. High-performance glazing may include multiple layers of glass or plastic, low-e coatings, and low-conductivity gas fill.
Also known as sustainable building or environmental building, this definition varies depending on the agency or group. Generally it means to construct a building to the highest environmental standards by minimizing the use of energy, water and materials. A green building, for example, might have skylights, recycled building materials and solar panels.
An adaptable term used to describe an array of products, technologies, and practices that use natural systems - or engineered systems that mimic natural processes - to enhance overall environmental quality and provide utility services. As a general principal, Green Infrastructure techniques use soils and vegetation to infiltrate, evapotranspirate, and/or recycle storm water runoff.
The Greenhouse Effect is a natural warming process of the earth. When the sun's energy reaches the earth some of it is reflected back to space and the rest is absorbed. The absorbed energy warms the earth's surface which then emits heat energy back toward space as long wave radiation. This outgoing long wave radiation is partially trapped by greenhouse gases such as carbon dioxide, methane and water vapor which then radiate the energy in all directions, warming the earth's surface and atmosphere. Without these greenhouse gases the earth's average surface temperature would be about 33 degrees Celsius cooler.
Some Greenhouse Gases (or GHG) occur naturally in the atmosphere, while others result from human activities. Naturally occurring greenhouse gases include water vapor, carbon dioxide, methane, nitrous oxide, and ozone. Certain human activities, however, add to the levels of most of these naturally occurring gases. Carbon dioxide is released to the atmosphere when solid waste, fossil fuels (oil, natural gas, and coal), and wood and wood products are burned. Methane is emitted during the production and transport of coal, natural gas, and oil. Methane emissions also result from the decomposition of organic wastes in municipal solid waste landfills, and the raising of livestock. Nitrous oxide is emitted during agricultural and industrial activities, as well as during combustion of solid waste and fossil fuels. Very powerful greenhouse gases that are not naturally occurring include hydro fluorocarbons (HFCs), per fluorocarbons (PFCs), and sulfur hexafluoride (SF6), which are generated in a variety of industrial processes. Emitted gases that are trapped in the atmosphere and contribute to climate change.
Rooftops planted with vegetation. Intensive green roofs have thick layers of soil (6 to 12 inches or more) that can support a broad variety of plant or even tree species. Extensive roofs are simpler green roofs with a soil layer of 6 inches or less to support turf, grass, or other ground cover. They provide evaporative cooling, convert carbon dioxide to oxygen, and reduce storm water runoff.
Independent, nonprofit organization that certifies a variety of products as environmentally responsible based on established criteria. Certified products include coffee filters, air chillers, paints and coatings, papers and newsprint, various cleaning products and services, windows and doors, and lodging properties.
Third-party certification program that identifies building products and materials which produce relatively low levels of emissions. Green Guard is administered by the nonprofit Green Guard Environmental Institute (GEI). Other GEI programs include the Children & Schools standard, which addresses emission standards for educational facilities, and the Green Guard for Building Construction Program...