Minister for the Environment and Water,
Having examined Federal Decree-Law No. (1) of 1972 concerning the remit of Ministries and the powers of Ministers, and its amendments, and
Federal Decree-Law No. (24) of 1999 concerning the protection and development of the environment, as amended, and
in accordance with Cabinet Decision No. (37) of 2001 regarding the executive regulations for the implementing regulations of Federal Decree-Law No. (24) of 1999 AD, concerning environmental protection and development,
Pursuant to Cabinet Decision No. (20) of 2008 regarding the regulation of the activities of crushing plants and quarries and the transport of their products, And pursuant to Cabinet Decision No. (27) of 2013 regarding the organisational structure of the Ministry, and
Ministerial Decision No. (110) of 2010 concerning the guidelines governing the planning, operation and implementation of Businesses operating in the field of crushers and quarries, and
Ministerial Decision No. (567) of 2014 concerning the Executive regulation governing the planning, operation and implementation of works Businesses operating in the field of crushing and quarrying, In the public interest,
Has decided:
Crushers and quarries must use on-site ambient air quality monitoring equipment in accordance with the requirements set out in the Annex No. (1) in the Annex to this Decision.
Crushers and quarries must install ambient air quality monitoring equipment in accordance with the requirements set out in Annex 2. Annexed to this Decision.
This Decision shall be published and shall come into force from the date of its issuance; any previous decisions that contradict or conflict with it shall be abrogated; and it shall be published in The Official Gazette.
Dr Rashid Ahmed bin Fahd
Minister for the Environment and Water
Published on: 2 Sha'ban 1436 AH
Corresponding to: 20 May 2015 AD
a) PM10 and PM2.5 Continuous monitoring capability
b) Accepted Methods:
a. Beta attenuation - Beta source: C14 (< 100 mCi)
b. Tapered Element Oscillating Microbalance (TEOM) - Differential
c. Nephelometers (Light Scattering Technology)
Standard cross-reference:
○ US EPA's Title 40 (CFR) Appendix J – Reference Method, PM10 in the Atmosphere
○ EPA's Title 40 CFR Part 50 Appendix L – Reference Method, PM2.5 in the Atmosphere
○ EPA's Title 40 CFR Part 58 Appendix D – Network Design Criteria for AAQM
○ EPA's Title 40 CFR Part 58 Appendix E – Probe & Monitoring Path Siting Criteria for AAQM
○ EN 12341:2014 for PM10
○ EN14907:2014 for PM2.5
All Methods used need to comply with the above International Standard
c) Calibrated on site during installation, and Quarterly ( Every 3 Months) against US EPA or EU approved cross reference method as listed above for both Mass and Flow Rate.
d) Concentration ranges: 0-1000 µg/m3 minimum (programmable) d) Detection limit: ≤ 10 µg/m3 for a 24hr cycle
e) Measurement cycles: ≤ 15 min-24hr (user selectable).
f) Air flow rate: ≤1.5 m3/hr with...