Unified UAE Legislation Database
Machine-read text — original PDF attached

Ministerial Decision No. 137 of 2012 concerning Guidelines for the regulation of activities carried out by enterprises operating in the cement industry

Status

In force

Issuing Authority

Ministry of Climate Change and Environment

Effective date

08 Apr 2012

Minister for the Environment and Water

  • Having regard to Federal Decree-Law No. 1 of 1972 on the Competencies of the Ministries and Powers of the Ministers, and its amending laws,
  • and Federal Decree-Law No. 1 of 1979 concerning the organization of industry affairs,
  • and Federal Decree-Law No. (3) of 1979 on Civil Defence, and the laws amending it,
  • and Federal Decree-Law No. 8 of 1980 on the Regulation of labour Relations, and its amending laws,
  • and Federal Decree-Law No. 3 of 1987 enacting the Penal Code, and the laws amending it,
  • and Federal Decree-Law No. (35) of 1992 enacting the Code of Criminal Procedure, and the laws amending it,
  • and Federal Decree-Law No. (24) of 1999 on the protection and development of the environment, and the laws amending it,
  • and Federal Decree-Law No. (1) of 2002 on the regulation and control of the use of radioactive sources and the prevention of the hazards they pose, and the laws amending it,
  • And pursuant to Cabinet Decision No. (37) of 2001 concerning the regulations for the Executive regulations for Federal Decree-Law No. (24) of 1999 on the protection and development of the environment,
  • Pursuant to Cabinet Decision No. (12) of 2006 concerning the Air Pollution Control Regulations,
  • Pursuant to Cabinet Decision No. (20) of 2008 concerning the regulation of the activities of crushing plants and quarries and the transport of their products,
  • Pursuant to Cabinet Decision No. (24) of 2011 concerning the regulation of the activities of establishments operating in the cement industry

Has decided:

Article (1)

Scope of Application

The provisions of this Decision shall apply to all existing and new establishments in the State, subject to any decisions issued by the competent authority.

Article (2)

Environmental Impact Assessment

Establishments are required to prepare an Environmental Impact Assessment (EIA) report through a specialist environmental consultancy with experience in the cement industry, in accordance with the Environmental Impact Assessment System for Establishments set out in Cabinet Decision No. (37) of 2001, which must include the following:

  • Monitoring air quality in the areas surrounding factories and the emissions they produce.
  • Measures taken to reduce fuel consumption and carbon dioxide emissions.
  • The use of alternative fuels and additives.

Article (3)

Health, Safety and Environment Management System

Establishments are required to put in place a health, safety and environmental management system, to keep a Register of these activities, and to monitor and follow up on health and safety activities.

Article (4)

Air Quality Monitoring

Facilities are required to measure the concentration of inhalable dust (PM 10) in the air surrounding the factory so that it does not exceed 150 micrograms percubic metre, using portable gas monitoring devices, and to submit monthly reports on air quality and particulate matter monitoring, as well as on flue gas emissions, to the Ministry and the competent authority.

Article (5)

Priorities for measurement and monitoring

1-5 To control the operations of the thermal furnace, the following must be measured continuously:

  • Pressure

  • Temperature

  • Oxygen content

  • Nitrogen oxides (NOx)

  • Carbon monoxide

  • SO₂ concentrations when SOx concentrations are high. 2.5 To determine the quantity of emissions accurately, continuous measurements must be taken of the following factors:

  • Exhaust volume

  • Humidity

  • Temperature

  • Dust

  • Oxygen

  • NOx

  • SO2

  • Carbon monoxide 3.5 Regular monitoring is carried out every six months to determine the concentrations of the following Articles:

  • Metals and their compounds

  • Total organic carbon

  • Hydrogen chloride

  • Hydrofluoride

  • Ammonia

  • Dioxins 4–5 The following parameters must be measured every six months, using the plant’s maximum operating power and under specific operating conditions:

  • Petrol/Toluene/Xylene

  • Polycyclic aromatic hydrocarbons (PAHs)

  • Other organic pollutants (chlorobenzene, PCBs and chloronaphthalene).

Article (6)

Control of airborne dust emissions

To control fugitive dust emissions resulting from the plant’s operational activities and weather conditions, using the following techniques:

  • Automated control devices and systems.

  • Protect articles susceptible to dust formation with a suitable cover.

  • Water mist and chemical dust suppressants.

  • Paving the roads used by lorries and machinery, and spraying the roads with water.

  • Dry cleaning carried out in conjunction with maintenance operations.

  • All systems operate using negative pressure technology to filter dust from the air via a fabric filter.

  • Enclosed storage for automated handling systems.

  • Further details can be found in Appendix 1.

Article (7)

Storage and handling of raw articles, clinker and cement

Storage areas for raw materials within the cement plant must be protected from dust emissions rising from the stockpiles (further details in Appendix 1).

  • Partially cover stockpiles of raw materials and prevent dust from becoming airborne by using a water spray system.
  • Clinker must be stored in silos or fully enclosed storage yards fitted with dry dust suppression systems (bag filters). The storage of clinker in open yards is prohibited, except in exceptional circumstances and for no longer than 10 days, provided it is adequately covered with waterproof sheeting, the competent authority is notified and special permission is obtained.
  • Equip raw material handling equipment, chimneys, conveyors and so on with an effective dust control system for control.
  • Pave the service roads within the factory or spray them with water to prevent dust from rising.

Article (8)

Fuel storage and handling

All types of liquid fuel must be stored in suitable storage tanks in accordance with the standards in force in the State, whilst solid fuels such as coal must be stored in suitably covered storage areas, and a water-based dust suppression system must be used to minimise emissions; coal handling equipment must be fitted with a suitable system to control dust emissions (further details in Annex (1)).

Article (9)

The Environment and the Green Belt

Facilities are required to plant sufficient trees to cover at least 50 per cent of their outer boundaries and to form a green belt around the factory, as well as to plant trees and vegetation within the factory grounds to improve the environment and the landscape. These must be trees that require minimal care and small amounts of water, such as the ghaf tree. Care must also be taken to ensure that the areas inside and around the factory are kept clean and well-maintained.

Article (10)

Waste generation and disposal

The main types of solid waste generated by the facilities are refractory bricks used to line smelting furnaces, cement kiln dust, and cement waste.

1.10 Factories grind solid waste from the refractory bricks lining smelting furnaces and either add it to the raw material mix or dispose of it by dumping it in designated waste areas.

2.10 Disposal of cement kiln dust by recycling it into the cement manufacturing process and blending it with the raw materials used to produce cement (clinker). In certain specific cases, the dust must be landfilled to reduce emissions and prevent the formation of certain chemical compounds from the mixture of raw materials and fuel; this must be done at a landfill site or in a Designated zone, as designated by the competent authority. Cement plants are required to prevent dust emissions by compacting the dust and spraying it with sufficient quantities of water, as it contains chemical components that may be harmful to health.

3.10 Dispose of cement waste or other fine waste in a safe manner within the designated area of the landfill site, and spray it with water to compact and stabilise the cement.

4.10 Recycling of all kiln feedstocks and cement waste alongside the clinker calcination process.

Article (11)

The use of solid fuel

The facility is committed to following best practices and utilising the best available technologies throughout all stages of production to minimise environmental impacts, whilst taking occupational health and safety into account during the plant’s operational activities.

When using coal as fuel for cement kilns, it must be handled correctly in accordance with best available techniques and burnt efficiently (Annex 1). The coal used must also meet the following quality specifications:

  • Total moisture content: 6%–15% (difficult to handle when levels are high, and dust emissions are low)
  • Content of fine particles (3 mm) not to exceed 25 per cent (excessively high levels cause handling problems)
  • Maximum ash content 25 per cent (to ensure the composition is compatible with the furnace feedstock)
  • Calorific value greater than 5,000 kilocalories per kilogram (depending on grinding capacity and output)
  • Sulphur: maximum 2 per cent

• Chlorine: maximum concentration 0.1 per cent

Article (12)

Dust emissions and deposition

1-12 All facilities are required to install modern bag-house filters to capture and reduce dust emissions, They shall also install additional bag-house filters with a capacity of not less than 25 per cent of the rated capacity of those filters, in order to capture dense dust emissions and prevent the risk of blockages and leaks in the other filters. 2.12 Plants are prohibited from releasing cement kiln dust into the air, and the level of cement dust emissions from chimneys must not exceed 40 mg/m³.

Article (13)

Air pollution

Establishments must comply with the maximum limits for air pollutants set out in the Air Pollution Control Regulations issued by Cabinet Decision No. (12) of 2006. Modern equipment for continuous monitoring must also be in place to ensure that emissions remain within the permitted limits.

Article (14)

Noise and vibration reduction

Noise and vibrations in facilities are minimised during production processes, and the following procedures must be followed:

  • Introduction of noise-insulating designs.
  • Register noisy activities for daytime hours only.
  • Proper maintenance of all mechanical equipment.
  • Use low-noise equipment.
  • Equipment cover.
  • The use of high-quality, sound-insulating articles in buildings.
  • Fitting rubber flooring in the frying pans and at the entrances to the chutes.
  • The use of appropriate personal protective equipment for workers.
  • Create a good green belt around the factory’s perimeter.
  • Install noise barriers near noisy operational equipment.

The noise level limits (measured per hour) in accordance with Cabinet Decision No. (12) of 2006 are set out in Register (1).

Register (1): Noise level limits in decibels

Night-time levels (dB A)
(7.00 – 22.00)
Times of day dB A
(22:00 – 7:00)
The region
30–4040–50Residential areas with light traffic
35–4545–55Residential areas in the city centre

Note: Weighted dB(A) is used to determine safe levels of noise exposure for humans

Article (15)

The use of alternative fuels

The combustion temperature in cement kilns is extremely high (< 1400°C) and is capable of completely incinerating waste – whether organic or inorganic – which is suitable for combustion alongside the raw cement mixture in the kiln, thereby helping to dispose of industrial waste that causes many problems in landfill sites. Waste that can be incinerated in these kilns includes the following:

  • Second-hand tyres.

  • Rubber.

  • Used paper.

  • Oil residues.

  • Wood scraps

  • Leaf litter.

  • Sewage sludge.

  • Plastic.

  • Solvent consumption

Using this waste as an alternative fuel has numerous environmental benefits, including reducing the use of fossil fuels, saving the energy used to dispose of waste in incinerators, and preventing groundwater pollution. Facilities that use, or intend to use, waste as a fuel source must obtain authorisation from the competent authority and the Ministry by providing details of the physical and chemical properties of the waste components and the proportion of waste to be incinerated alongside the primary fuel.

All establishments must comply with and follow these regulatory guidelines.

All relevant authorities shall implement this Decision within their respective remits; it shall be published in the Official Gazette and shall come into force on the date of its issuance.

Dr Rashid Ahmed bin Fahd
Minister for the Environment and Water

Published on: 16 Jumada al Awwal 1433 AH Corresponding to: 8 April 2012 AD

Establishments shall implement the following measures to effectively prevent and reduce fugitive dust emissions in the parts mentioned:

MControl measuresGuidelines
1Areas where articles are unloaded must be covered.Cover both sides of the unloading area with a flexible and durable fabric tarpaulin that reaches the edge of the unloading tipper’s roof.
2Spray water onto the articles before and during the unloading process.- Fit the dust suppression system with a water spray system.
- Use a suitable design for the water spray system to ensure optimum use of the sprayed water.
- Adopt suitable systems to prevent moving parts from slowing down or coming to a standstill.
MControl measuresGuidelines
1Adequate coverage of material transfer points.Ensure all areas are covered whilst allowing access to the doors, which must remain closed during the handling process, and ensure that any spilled liquids are removed regularly.
2Control of airborne dust at transport sites and during transport operations.- Fit the dust suppression system with a water spray system.
- Use a suitable design for the water spray system by equipping it with a system to suppress airborne dust or by dry collection using a filter (cum bag) of sufficient and appropriate collection capacity.
MControl measuresGuidelines
1Set aside a space or area for storing coal.Put up a sign clearly indicating the designated storage area.
2The vehicle access routes in the coal storage yard must be paved.Provide the corridors with suitable entry and exit points.

#4. Clinker Cooling Part

GuidelinesControl measuresM
The following details must be provided for new installations:
- The unit which may require the addition or installation of the necessary equipment to separate fine particles from the electrostatic precipitator of the clinker cooler.
- The separation of fine particles may be achieved by passing the dust collection system through the clinker cooler, so that the fine particles are separated and the coarse particles can be recycled, whilst the fine particles are either recycled into the clinker storage silo or disposed of safely.
Fine particulate matter emitted and extracted from the clinker cooler must be separated using filters designed for this purpose.1
GuidelinesControl measuresM
Install a bag filter before the gases are vented.Storage of clinker in a steel silo (Silor).1
An appropriate ventilation system must be installed during the clinker handling and grinding stages. The shut-off gate must also be fitted with a mechanical system or flexible rubber belts.Provision of a ventilation system for the covered clinker plant, utilising a dry dust filter (bag filter).2
GuidelinesControl measuresM
Filling machines are fitted with a dust extraction system; the filling process can be carried out under negative pressure, with dust being captured in bag filters.Use of a dust extraction system for packaging machines.1
Install a ventilation system to extract airborne particles and ensure a suitable working environment.Ensure adequate ventilation in the packing area.2
GuidelinesControl measuresM
Carry out appropriate maintenance on paved roads through the regular use of dry cleaning machines and water spraying, as well as carrying out any necessary repairs.Road construction and maintenance.1
Set speed limits of between 10 and 15 km/h to reduce rising emissions.Setting minimum speed limits.2

 

 

Appendix-2

Controlling Air Pollution during Cement Plant Operations (Reference Document Only)

The main constituents of exhaust gasses from cement kilns are nitrogen, carbon dioxide, oxygen and moisture. The exhaust gasses also contain small quantities of dust, chlorides, fluorides, sulfur dioxide, carbon monoxide and still smaller quantities of organic compounds...