Unified UAE Legislation Database

Fujairah Circular No. 86/FMBL/2017 of 2017 Recommendations for Mix design

Status

In force

Issuing Authority

Fujirah Municipality

Effective date

XX.XX.XXXX

Official Link

https://

Ref No: 86/FMBL/2017  Date: 10/12/2017

Managers

Ready Mix-Concrete

Subject: Recommendations for Mix design

To reduce abnormal behavior of concrete, we were intensively monitoring and researching on Concrete Mix designs and planned to assign cement & water cement ratio fixed for concrete grades.

 

Compressive strength class cube

Cement (OPC / SRC)

Water / Cement ratio

C30

370

0.44

C35

380

0.42

C40

400

0.40

C45

420

0.36

C50

430

0.35

 

Following above mentioned chart you must submit mix design to us immediately. We know out of these, concrete strengths may vary due to aggregate sizes and quality also.

So, you are instructed to inform us during any changes of suppliers or materials.

With this you are also instructed to mention on Concrete Delivery Slip

1. Actual Concrete grade (As per Batch Plant)

2. Client details

3. Plot no

4. Location

5. Structure    

 

Chief of Lab