STANDARD
Department: Quality Improvement Department
Document Identifier: SD/HCO/010/02
STANDARD – Dental Services
1. PURPOSE
1.1 These Standards define the requirements to ensure acceptable minimum levels of quality, performance, safety, and reliability of dental services operating in Dubai Healthcare City (DHCC). These Standards define the licensing criteria, qualified personnel, and service requirements for the provision of dental services in DHCC.
2. SCOPE OF APPLICATION
2.1 These Standards are applicable to all Healthcare Operators (HCOs) and Healthcare Professionals (HCPs) currently providing or intending to provide dental services within DHCC. 2.2 Healthcare Operators using Procedural Sedation and Analgesia within Dubai Healthcare City must follow Standards for Procedural Sedation and Analgesia (PSA) in addition to these standards. 2.3 Healthcare Operators using Nitrous Oxide must follow the policy on Managing Anxious Children by use of Sedation in Pediatric Dentistry.
3. STANDARD
3.1 LICENSURE OF DENTAL CLINICS:
3.1.1 Dental services may be provided by DHCA Licensed Healthcare Operators holding a Clinical Operating Permit for Single and Multi-Specialty Outpatient Clinics, Outpatient Surgical Clinics, Hospitals and other Inpatient Healthcare Facilities in accordance with the requirements of the Standards defined herein. In issuing a Clinical Operating Permit and in renewing a Clinical Operating Permit, the Registry of Companies shall determine the appropriate 'Type', 'Class', 'Scope' and 'Clinical Specialties' for each Licensed Healthcare Operator providing dental services. Clinical specialties that can be provided within the scope of Dental Services are Endodontics, General Dentistry, Orthodontics, Pediatric Dentistry, Periodontics, Prosthodontics, and Oral and Maxillofacial Surgery. 3.1.2 Each Licensed Healthcare Operator providing dental services must provide such services in accordance with all applicable regulations, rules, policies, and standards of DHCA.
3.2 QUALIFIED PERSONNEL:
3.2.1 Each Licensed Healthcare Operator providing dental services must appoint qualified personnel and maintain staffing levels as required to ensure reliable and consistent care in compliance with these Standards, the DHCR Outpatient Clinic Quality Standards or the appointed accreditation organization's standards, the DHCR Quality Oversight Policies, and any other applicable regulations, rules and standards.
STANDARD – Dental Services
| 3.2.2 | Each Licensed Healthcare Operator providing Dental Services must employ a Dental Director and an Administrative Manager. The Dental Director must be a Licensed Dentist who may also serve as the Administrator. |
| 3.2.3 | The Dental Director will have full time responsibility for oversight of all clinical services to ensure safe and quality healthcare service delivery as per the Standards for Outpatient Clinical Services. |
3.3 PATIENT MANAGEMENT:
| 3.3.1 | Each Licensed Healthcare Operator providing dental services must manage patient care in accordance with these Standards, the DHCR Outpatient Clinic Standards, guidelines and all other applicable laws, regulations, and standards. |
STANDARD – Dental Services
| 3.3.2 | Patients shall be accepted for healthcare services based on whether the facility's scope of clinical activities, services and availability of suitably qualified and licensed healthcare professionals can meet the patient's needs. |
| 3.3.3 | An intraoral and extra oral examination must be conducted on all patients during the initial assessment to determine the proper diagnosis. |
STANDARD – Dental Services
| 3.4 | HEALTH INFORMATION MANAGEMENT: |
|---|
| 3.4.1 | Each Licensed Healthcare Operator providing dental services must comply with DHCA regulations, policies and standards for the management of patient health information and medical records policy. |
| 3.4.2 | Each Licensed Healthcare Operator providing dental services must ensure the confidentiality of patient health information as per the provisions of the DHCA Health Data Protection Regulation No. (7) of 2013 and Federal Law No. 2 of 2019 on the use of information technology and communications in the healthcare sector. |
| 3.5 | PATIENTS RIGHTS AND RESPONSIBILITIES: |
|---|
| 3.5.1 | Each Licensed Healthcare Operator providing dental services must provide patients and families with information regarding the DHCA Patients' Rights and Responsibilities in accordance with Schedule two of the DHCA Governing Regulation No. (1) of 2013. This information must also be displayed in English and Arabic throughout the facility for patients and visitors to review. |
STANDARD – Dental Services
| 3.5.2 | Each Licensed Healthcare Operator providing dental services is responsible for providing processes that support patients' and families' rights during care. |
| 3.5.3 | Patient Informed Consent must be obtained through a defined process and carried out by trained staff in a manner and language the patient can understand in accordance with the DHCR Informed Consent Policy. |
| 3.6 | MINIMUM FACILITY REQUIREMENTS |
| 3.6.1 | Each Licensed Healthcare Operator providing dental services must comply with the minimal facility requirements of the most current FGI Guidelines for Design and Construction of Hospitals and Outpatient Facilities. The design shall make provision for accessible, efficient, and safe clinical care in a secure, supportive, and functional environment. |
STANDARD – Dental Services
| 3.6.12 | Dental Radiology Requirements:
3.6.12.1 Healthcare Operators offering Dental Radiology Services must get the approval / license from the Federal Authority for Nuclear Regulation (FANR), UAE and comply with their regulations.
3.6.12.2 Individual monitoring for workers through dosimeters must be conducted for any worker who is likely to receive more than 10% of the annual dose limit of 20mSv in any one year (i.e. 2mSv/yr) as per FANR requirements.
3.6.12.3 Risk assessment / evaluation shall be carried out for monitoring radiation exposure to the staff (For details see Appendix 1). |
| 3.7 | IN HOUSE STERLIZATION REQUIREMENTS: |
|---|
| 3.7.1 | Each Licensed Healthcare Operator providing dental services must have an assigned and dedicated area for sterilization. |
| 3.7.2 | Written policies and procedures on sterilization and manufacturer reprocessing instructions for reusable instruments must be available to ensure reusable patient care instruments and devices are reprocessed appropriately. |
STANDARD – Dental Services
| 3.7.13 | Dental hand pieces (including the low-speed motor) and other devices not permanently attached to air and waterlines are to be cleaned and heat-sterilized according to manufacturer instructions. |
| 3.7.14 | A chemical indicator must be used inside each package. If the internal indicator is not visible from the outside, an exterior chemical indicator must also be used on the package. |
| 3.8 | REQUIREMENTS FOR DENTAL UNITS WATERLINES, BIOFILM CONTROL AND WATER QUALITY: |
| 3.8.1 | Dental unit water quality must be maintained as per Dubai Municipality recommendations of Total Bacterial Count (TBC) of 200 CFU / mL as a maximum for contamination of water used in dental treatments. And Legionella bacteria must not be detected in any sample. |
STANDARD – Dental Services
| 3.8.6 | Manufacturer's recommendations must be followed for the method of maintaining acceptable water quality, water delivery system, and the recommended frequency of monitoring |
| 3.8.7 | Appropriate measures must be taken to control formation of biofilm in waterlines and to control legionella bacteria. In cases where the test results are positive, appropriate actions for treatment must be taken immediately and records of the same must be maintained. |
| 3.9 | QUALITY OVERSIGHT AND ACCREDITATION: |
| 3.9.1 | Each Licensed Healthcare Operator is required to successfully meet the DHCR Outpatient Clinic Quality Standards and to obtain Certification of Successful Completion of the Quality Survey performed by the Clinical Affairs Department of DHCR within (2) years of commencing operations, and maintain such certification throughout the term of its Clinical Operating Permit in accordance with the requirements of the DHCA Healthcare Operators Regulation No. (4) of 2013. |
| 3.10 | DENTAL LABORATORY REQUIREMENTS: |
| 3.10.1 | Healthcare Operators operating a stand-alone dental lab must obtain a license / clinical operating permit from Dubai Healthcare City Authority- Regulatory (DHCR) to operate a dental laboratory in Dubai Healthcare City. |
STANDARD – Dental Services
| 3.10.6 | Any material or dental work entering or leaving the lab must maintain strict hygiene conditions. Proper disinfection of materials/ impressions entering and leaving the laboratory must be ensured. |
| 3.10.7 | Proper aspiration and ventilation must be in place. |
| 4 | DEFINITIONS |
| 4.1 | ALARA: As Low as Reasonably Achievable |
STANDARD – Dental Services
| 4.15 | Safety: the condition of being protected against physical, psychological, or other types or consequences of failure, error, or harm, which could be considered non-desirable. This can take the form of being protected from the event or from exposure to something that causes health losses, for example, the use of a drug, or a procedure, or risk in the care environment. |
| 4.16 | Scope of Practice of Dentistry: the Professional Practice involving the evaluation, diagnosis, prevention, or treatment, including non-surgical, surgical, or related procedures, of diseases, disorders, or conditions of the oral cavity, maxillofacial area, or the adjacent and associated structures, and the impact of the disease, disorder, or condition on the human body. |
5 APPENDICES (as applicable)
| 5.1 | Appendix 1 – Risk Assessment |
6 REFERENCE
| 6.1 | Basic Safety Standards for Facilities and Activities involving Ionizing Radiation other than in Nuclear Facilities (FANR-REG-24) Version 1, Federal Authority for Nuclear Radiation, United Arab Emirates. |
| 6.2 | CDC Guidelines for Infection Control in Dental Health-Care Settings 2003, Morbidity and Mortality Weekly Report (MMWR) December 19, 2003 / 52(RR17);1-61 |
STANDARD – Dental Services
Appendix 1
The Risk Assessment
A 10% evaluation is a documented evaluation by the facility that a worker is not likely to receive more than 10% of the annual occupational Dose limits in Article (10) of FANR-REG-24. This evaluation can be done on the basis of prior experience, such as doses measured by the licensee or doses measure by others in similar situations; area surveys; or a calculation, based upon source strength, distance, shielding, and time spent in the work area.
The Risk Assessment shall estimate all expected annual staff doses arising from the use of X-ray equipment in the practice and should take account of the following considerations:
- Identification of people at risk
- Realistic workload i.e., number of X-rays taken
- Type of X-ray unit(s) used
- Radiation output of the X-ray unit(s)
- Types of scans performed
- Layout of the surgery and structural shielding
- Operator position
- The likelihood of recording a reportable dose (i.e. an effective dose greater than 2 mSv in a year)
- Previous dose records for the staff performing similar work
This list is not exhaustive and other considerations, such as local policies, should also be taken into account.
The risk assessment shall be documented and retained on file by the dentist and may be requested during inspection by the local authorities.