Unified UAE Legislation Database
Machine-read text — original PDF attached

Dubai Administrative Decision No. 13 of 2025 Approving the Preventive Systems Manual

Status

In force

Issuing Authority

SIRA

Effective date

30 May 2026

The Chief Executive Officer of the Security Industry Regulatory Agency,

After perusal of:

Law No. (12) of 2016 Regulating the Security Industry in the Emirate of Dubai and its amendments; and

Board of Directors Resolution No. (1) of 2018 Issuing the Implementing Bylaw of Law No. (12) of 2016 Regulating the Security Industry in the Emirate of Dubai,

Does hereby issue this Resolution.

Article (1)

a. Pursuant to this Resolution, the attached Preventive Systems Manual, inclusive of the requirements and technical standards set forth therein, is approved.

b. The Security Industry Regulatory Agency must publish the Manual approved pursuant to paragraph (a) of this Article, together with any amendments thereto, on its website.

Article (2)

The Manual approved under this Resolution applies to all establishments specified in the above-mentioned Board of Directors Resolution No. (1) of 2018.

Article (3)

Any provision in any other administrative resolution or manual is hereby repealed to the extent that it contradicts the provisions of this Resolution or the Manual attached hereto.

Article (4)

This Resolution will be published in the Official Gazette and will come into force on the day on which it is published.

Khalifa Ibrahim Al Saleis Chief Executive Officer Security Industry Regulatory Agency

Issued in Dubai on 14 April 2025

Corresponding to 16 Shawwal 1446 A.H.

Contents

Definitions ... 6 Part One: Technical Specifications and Controls ... 7 Chapter One: Digital Systems Specifications (IP) ... 8 Chapter Two: Specifications of Access Control Systems ... 15 Chapter Three: Specifications for Alarm and Intruder Detection Systems ... 17 Chapter Four: Locks Specifications ... 20 Chapter Five: Specifications of Penetration-Resistant Glass ... 20 Chapter Six: HVM Barriers Specifications (External Perimeter Safety) ... 20 Part Two: Operational Controls ... 22 Chapter One: Operational Image Requirements ... 24 Chapter Two: Remote Communication Requirements ... 27 Chapter Three: Management and Operation ... 27 Chapter Four: Security Lighting ... 28 Chapter Five: Image Acceptance ... 28 Chapter Six: The Sustainability of Security Systems ... 29 Chapter Seven: Maintenance, Development and Modification of Security Systems ... 31 Chapter Eight: Prohibitions ... 32 Chapter Nine: Exceptional Cases ... 32 Chapter Ten: Quality of Work and Installation ... 33 Part Three: Security Requirements and Conditions ... 34 Chapter One: Security Conditions and Requirements for Luxury Hotels: ... 35 Chapter Two: Security Conditions and Requirements for Tourist Hotels: ... 38 Chapter Three: Security Conditions and Requirements for Shopping Malls: ... 41 Chapter Four: Security Conditions and Requirements for Important Complexes: 44 Chapter Five: Security Requirements for Labor Accommodations: ... 55 Chapter Six: Security Conditions and Requirements for Cinemas and Theaters: 57 Chapter Seven: Security Conditions and Requirements for Amusement Parks: .. 59 Chapter Eight: Security Conditions and Requirements for Educational Facilities: 61 Chapter Nine: Security Requirements for Healthcare Facilities: ... 66 Chapter Ten: Security Requirements for Non-Muslim Places of Worship: ... 69

Chapter Eleven: Security Requirements for the Manufacture and Sale of Precious Metals and Gemstones:... 70 Chapter Twelve: Security Requirements for Financial and Monetary Institutions: ... 76 Chapter Thirteen: Security Requirements for Sports and Recreational Halls and Clubs: ... 88 Chapter Fourteen: Security Requirements for Gas Stations: ... 89 Chapter Fifteen: Security Requirements for Large and diverse Stores:... 90 Chapter Sixteen: Security Requirements for Electronic Games and Entertainment Halls and Arenas: ... 94 Chapter Seventeen: Security Requirements for Football Clubs: ... 96 Chapter Eighteen: Security Requirements for Warehouse compounds: ... 98 Chapter Nineteen: Security Requirements for Warehouses: ... 99 Chapter Twenty: Security Requirements for Self-storage: ...102 Chapter Twenty-One: Security Requirements for Air Cargo: ...107 Chapter Twenty-Two: Security Requirements for Factories: ...109 Chapter Twenty-Three: Security Requirements for Vacation Homes: ...112 Chapter Twenty-Four: Security Requirements for Shooting Ranges:...113 Chapter Twenty-Five: Security Requirements for Art Galleries: ...114 Chapter Twenty-Six: Security Requirements for Vehicle Rental Shops: ...116 Chapter Twenty-Seven: Security Requirements for Tobacco Retail Stores: ...117 Chapter Twenty-Eight: Security Requirements for Precious Goods Stores: ...118 Chapter Twenty-Nine: Security Requirements for Data Centers: ...120 Chapter Thirty: Security Requirements for Pharmacies: ...122 Chapter Thirty-One: Security Requirements for Massage Centers: ...123 Chapter Thirty-Two: Security Requirements for Parking Rental and Management Services: ...124 Chapter Thirty-Three: Security Requirements for Auction Halls:...125 Chapter Thirty-Four: Security Requirements for Customer Happiness Centers: 126 Chapter Thirty-Five: Security Requirements for Business Centers: ...127 Chapter Thirty-Six: Security Requirements and Conditions for Quran Memorization Centers and Islamic Institutions: ...128 Chapter Thirty-Seven: Security Requirements for Charitable Organizations:...130 Chapter Thirty-Eight: Security Requirements for Hunting Equipment Stores: ...132 Chapter Thirty-Nine: Security Requirements and Conditions for the Security Monitoring Operations Center:...133 Chapter Forty: Security Requirements for the Transport of Money and Valuable Materials: ...135 Chapter Forty-One: Security Requirements for Vehicle safety and Protection: ..138 Chapter Forty-Two: Security Requirements for Transfer and Delivery of

Money:...139 Chapter Forty-Three: Communication and Communicating Requirements for Security guard Service Providers:...140

Definitions

SNTermDefinition
1EstablishmentIt includes vital sectors, important complexes and the like, specified in accordance with the provisions of the Executive Regulations of Law No. (12) of 2016 regarding the regulation of the security industry in the Emirate of Dubai.
2Establishment EntrancesAll entrances and exits to the establishment, including emergency exits.

Part One: Technical Specifications and Controls

First: Cameras

SNSpecificationsRemarks
1They must be in color.-

Second: Recording devices

A. General Specifications:

SNSpecificationsRemarks
1Only digital recording devices must be used-
2The recording resolution must be at least 1080p Full HD.-
 less than 31 days 
11The recording devices must be computed with 20% extra capacity.-
27Ability to recognize and write on Windows-compatible storage media of various capacities.-
28Recording files shall be in standard formats that can be viewed directly on the multimedia player software available in Windows operating system.-

B. Additional Specifications of Vehicles Recording Devices:

SNSpecificationsRemarks
1The ability to record, display, and extract recordings simultaneously.-
2A display screen must be installed within the driver's and assistant's line of sight.-

C. Recording Duration and Quality:

The recording must be kept for at least 31 days, at high quality, and at a frame rate of at least 10 frames per second.

Third: Display devices

SNSpecificationsRemarks
1All monitors shall be of high operational specifications to be suitable for continuous operations without interruptions for a period not less than three years.Monitors must be designed for continuous work 24/7 - 365 days.
2The monitor's resolution should not be less than Full HD 1080p.-
  less than 12 x 6.7 cm in the display monitor.
6The number of monitors required for displaying cameras' imaging shall be calculated with considering critical and normal camerasAs described in the following paragraphs No. 7,8
SNSpecificationsRemarks
1Where twisted pairs are used, the type used must contain a minimum of high-quality copper known as CAT 6.Cables (copper clad aluminum) and (copper clad iron) are not allowed.
SNSpecificationsRemarks
1Only digital recording devices must be used-
2The recording resolution must be at least 1080p Full HD.-
 less than 31 days 
11The recording devices must be computed with 20% extra capacity.-
27Ability to recognize and write on Windows-compatible storage media of various capacities.-
28Recording files shall be in standard formats that can be viewed directly on the multimedia player software available in Windows operating system.-
SNSpecificationsRemarks
1The ability to record, display, and extract recordings simultaneously.-
2A display screen must be installed within the driver's and assistant's line of sight.-
SNSpecificationsRemarks
1All monitors shall be of high operational specifications to be suitable for continuous operations without interruptions for a period not less than three years.Monitors must be designed for continuous work 24/7 - 365 days.
2The monitor's resolution should not be less than Full HD 1080p.-

First: General specifications

  less than 12 x 6.7 cm in the display monitor.
6The number of monitors required for displaying cameras' imaging shall be calculated with considering critical and normal camerasAs described in the following paragraphs No. 7,8

Second: Locking mechanisms

SNSpecificationsRemarks
1Where twisted pairs are used, the type used must contain a minimum of high-quality copper known as CAT 6.Cables (copper clad aluminum) and (copper clad iron) are not allowed.

Third: Connectors

SNSpecificationsRemarks
1Wireless connections may not be used without SIRA approval.-
 type, in accordance with international specifications and standards. 

Fourth: Control Panel

SNSpecificationsRemarks
1All control panels must be equipped with a backup battery to ensure continued operation during a main power outage for at least 4 hours.-
2Systems must be built based on communication over the digital network.-

Fifth: Management and Control Software

SNSpecificationsRemarks
1must work on different platforms and operating systems.-
2To retain login and logout details for all linked devices for a period of no less than one year.-

Chapter Three: Specifications for Alarm and Intruder Detection Systems.

All system components must be third generation at a minimum.

First: Sensors

SNSpecificationsRemarks
1The sensors field must cover protected areas so that no area can be breached to stop or disable the security system.-
2Dual-technology motion detectors, such as infrared and microwaves, should be used.-

Second: Visual and audible alarm and warning devices

SNSpecificationsRemarks
1The alarm (audio and visual) must be installed, equipped with a loudspeaker, and a flashing light that attracts attention.-
2The device's ringing duration must be set for at least 5 minutes or until the alarm is reset.-

Third: Connectors

SNSpecificationsRemarks
1Connectors must be wired. Wireless connection of sensors may only be used after obtaining prior written approval from SIRA.-
2Each sensor must be connected separately to the control and alarm panel and to a single zone.-
3All system wires must be kept inside dedicated conduits.-
4Alarms must not be installed outside the facility, except for flashing lights and sirens.-
SNSpecificationsRemarks
1The Alarm system control panel must be approved by SIRA.-
11The control panel must be equipped with a backup battery that can operate for 8 continuous hours.-
SNSpecificationsRemarks
1The facility manager must activate the alarm system after the end of the working day or after evacuating the building.-
2The person in charge or assigned to the protected facility must respond to an alarm or emergency.-

Pry-resistant, puncture-resistant, and shear-resistant locks with high-quality security keys must be installed, based on Standard No. 2320:2012(E) Lock Standards, Fittings, Requirements, and Test Methods.

First: General Specifications

SNSpecificationsRemarks
1The force resistance on the cylinder plug or locking mechanism must not be less than 10 kN.-

First: General Specifications

SNSpecificationsRemarks
1Piercing-resistant glass or the use of piercing-resistant films attached to a strong frame, on the facility's glass facades so that the glass resists penetration for at least 90 seconds.-

These are used to control and block vehicle traffic to prevent intrusion attempts.

First: Standards

HVM must be appropriate for the location. Based on the nature of the location, the category is determined from the table in point 5 below, considering that they must be approved by SIRA in accordance with established procedures.

Second: HVM Types Based on Shape (various shapes and styles are designed for this purpose):

SNTypeRemarks
1strong walls-

Third: Types of HVM from an operational perspective

SNTypeRemarks
1Movable HVM, meaning they can be temporarily deactivated (by moving, folding, or retracting them) to allow vehicles to pass through them, and then return to their original position. This is done manually or mechanically by authorized persons.-

Fourth: Requirements

SNSpecificationsRemarks
1SIRA approval (prior to implementation) must be obtained for the locations, design, and calculations of all types of HVM for each project.-

Fifth: Installation requirements

SNSpecificationsRemarks
1Light
• Vehicle weight: 1,500 kg
• Vehicle type: Lightweight, two-wheel drive, with a rigid axle
• Impact speed: 110 km/h
• Impact angle: 90 degrees
• Penetration distance: 0 meters
-
 Vehicle weight: 7,500 kgVehicle type: Medium-sized four-wheel drive with rigid 2-axle axlesImpact speed: 80 km/hImpact angle: 90 degreesPenetration distance: 0 meters 
3HeavyVehicle weight: 32,000 kgVehicle configuration: Heavy, 6x6, 4-wheel drive Rigid axle 4-linkImpact speed: 80 km/hImpact angle: 90 degreesPenetration distance: 0 meters-

Part Two: Operational Controls

First: Field of View

  1. Inspection Field of View
SNDescriptionRemarks
1The target image size must not be less than 400% of the viewing size of the display screen. In exceptional cases and with the prior approval of the institution, the density of image elements may be used, such that it is not less than 1000 pixels per meter.The camera should be positioned directly in front of the subject (the target) so that the center of the image is the spot between the eyes of a "standard target," which is an average height of 1.6 meters. The camera can be positioned at a horizontal angle of no more than 10 degrees to the right or left, and a vertical angle of no more than 10 degrees above or below the horizon.
  1. Identification View
SNDescriptionRemarks
1The face must be the most prominent part of the image. The target image size must be at least 120% of the screen's viewing area. In exceptional cases, with the prior approval from SIRA, an image element density of at least 300 pixels per meter may be used.* The camera is mounted directly in front of the person (target). The camera can be mounted at a horizontal angle of no more than 45 degrees to the right or left, and a vertical angle of no more than 20 degrees above or below the horizon.

* Wide Dynamic Range (WDR) feature is required for cameras used for identification, regardless of their installation location. The WDR contrast ratio must be at least 110 dB.
  1. Recognition View
SNDescriptionRemarks
1The entire body and its immediate surroundings should be the most prominent part of the image. Therefore, the target image size should not be less than 50% of the viewing area of the display. In exceptional cases, and with prior approval from SIRA, an image element density of no less than 125 pixels per meter may be used.The camera is mounted to recognize a "standard target" of 1.6 meters in length from any angle to the right or left and a vertical angle of no more than 45 degrees above the horizon.

4. Observation View

 less than 31 days 
11The recording devices must be computed with 20% extra capacity.-

5. Detection View

27Ability to recognize and write on Windows-compatible storage media of various capacities.-
28Recording files shall be in standard formats that can be viewed directly on the multimedia player software available in Windows operating system.-

6. Monitoring View

SNSpecificationsRemarks
1The ability to record, display, and extract recordings simultaneously.-
2A display screen must be installed within the driver's and assistant's line of sight.-

7. View of recognizing vehicle plates number (ANPR / NPR)

SNSpecificationsRemarks
1All monitors shall be of high operational specifications to be suitable for continuous operations without interruptions for a period not less than three years.Monitors must be designed for continuous work 24/7 - 365 days.
2The monitor's resolution should not be less than Full HD 1080p.-
  less than 12 x 6.7 cm in the display monitor.
6The number of monitors required for displaying cameras' imaging shall be calculated with considering critical and normal camerasAs described in the following paragraphs No. 7,8

Chapter Two: Remote Communication Requirements

SNSpecificationsRemarks
1Where twisted pairs are used, the type used must contain a minimum of high-quality copper known as CAT 6.Cables (copper clad aluminum) and (copper clad iron) are not allowed.

Chapter Three: Management and Operation

SNSpecificationsRemarks
1Wireless connections may not be used without SIRA approval.-

Chapter Four: Security Lighting

 type, in accordance with international specifications and standards. 

Chapter Five: Image Acceptance

SNSpecificationsRemarks
1All control panels must be equipped with a backup battery to ensure continued operation during a main power outage for at least 4 hours.-
2Systems must be built based on communication over the digital network.-

Chapter Six: The Sustainability of Security Systems

SNSpecificationsRemarks
1must work on different platforms and operating systems.-
2To retain login and logout details for all linked devices for a period of no less than one year.-
SNSpecificationsRemarks
1The sensors field must cover protected areas so that no area can be breached to stop or disable the security system.-
2Dual-technology motion detectors, such as infrared and microwaves, should be used.-

Chapter Seven: Maintenance, Development and Modification of Security Systems

SNSpecificationsRemarks
1The alarm (audio and visual) must be installed, equipped with a loudspeaker, and a flashing light that attracts attention.-
2The device's ringing duration must be set for at least 5 minutes or until the alarm is reset.-

Chapter Eight: Prohibitions

SNSpecificationsRemarks
1Connectors must be wired. Wireless connection of sensors may only be used after obtaining prior written approval from SIRA.-
2Each sensor must be connected separately to the control and alarm panel and to a single zone.-

Chapter Nine: Exceptional Cases

3All system wires must be kept inside dedicated conduits.-
4Alarms must not be...