Department: Quality Improvement
Document Identifier: DHCR/SD/HCO/012/01
Laboratory services are an essential component of quality healthcare delivery at every level of the healthcare system. Laboratory services are required to support clinical diagnosis, rationalize and monitor treatment/therapy, for the screening for epidemiological purposes, surveillance and control of diseases of public health importance, and to provide early warning of disease outbreaks.
A Diagnostic Clinical Laboratory is a laboratory where tests are usually done on clinical specimens; body fluids such as blood, urine, sputum, stool, cerebrospinal fluid (CSF), peritoneal fluid, pericardial fluid, and synovial fluid, as well as other specimens, in order to obtain information about the health of a patient as pertaining to the diagnosis, treatment, and prevention of disease.
Diagnostic Clinical Laboratories may provide different investigations as follows;
A Non-Diagnostic Medical Laboratory may include:
| 1.1 | This standard and the supporting documents (appendix 1,2 and 3) defines the minimum requirements including licensing and service specifications to ensure acceptable minimum levels of quality, performance, safety and reliability for the use and management of Laboratory activities within Dubai Healthcare City (DHCC). |
| 1.2 | This standard and the supporting documents (appendix 1,2 and 3) address issues which are generic across the laboratories such as qualified personnel, scope of practice and service limitations for the provision of Laboratory activities in DHCC. |
| 2.1 | This Standard is applicable to all Healthcare Operators and Healthcare Professionals licensed under Diagnostic or Non-Diagnostic Laboratory within DHCC. |
| 2.2 | This standard is applicable to all healthcare professionals and healthcare organizations providing laboratory services. |
| 3.1 | LICENSURE OF LICENSED HEALTHCARE OPERATOR (HCO) PROVIDING LABORATORY SERVICES / QUALIFIED PERSONNEL 3.1.1 Clinical Laboratory license shall be issued on three main categories: 3.1.1.1 Licensed Hospital Laboratory; laboratories which are part of a hospital and receive samples from the same hospital, as well, as other healthcare operators and may act as a reference laboratory. 3.1.1.2 Diagnostic clinical or medical laboratory; standalone laboratories that may receive clinical samples from practitioners, or clinical research sites for analysis. 3.1.1.3 Licensed Non-Diagnostic Medical Laboratory; for Stem cell processing and storage, Cryopreservation, Blood Bank, Embryology, Therapeutic Biological Product Manufacturing, etc. 3.1.2 Each Healthcare Operator providing Laboratory Services shall comply with this standard, equivalent accreditation standards, and other applicable DHCR regulations, standards and policies. 3.1.3 Each Healthcare Operator providing Laboratory Services shall appoint appropriately qualified Licensed Healthcare Professionals, as per DHCA Healthcare Professionals Licensure requirements, to deliver the services consistent with type of services provided. |
| of clinical knowledge and skills, education and training; monitoring s staff competency and clinical evaluation of the laboratory staff. 3.1.8.8 Provide a safe and adequate laboratory environment and facilities. 3.1.8.9 Plan and provide adequate resources for the provision of laboratory services, essential equipment and ensuring its functionality and maintenance. 3.1.8.10 Ensure an adequate supply of laboratory chemicals, reagents, test kits and supplies. 3.1.8.11 Establish an effective system for documentation and recordkeeping. 3.1.8.12 Establish and monitor an effective quality management system (QMS) including internal, and external quality control, covering all aspects of laboratory operations; proficiency testing program, developing, implementing, approving and maintaining standards, policies and procedures. 3.1.8.13 Ensure adequate communication with laboratory users, including patients and clients. 3.1.8.14 Provide for required services either directly, or through referral to another laboratory and assure the consistent performance of reference and contract laboratory services in accordance with DHCR laboratory standards, when they are used. 3.1.8.15 Establish practices that respect the needs of patients, including providing privacy, security, and confidentiality of information. 3.1.8.16 Monitor turnaround time, and other analytical parameters. 3.1.8.17 Manage customer complaints and monitor patient satisfaction. 3.1.8.18 Oversee and verify tests results as appropriate. 3.1.8.19 Design and implement a contingency plan to ensure that essential services are available during emergency situations or other conditions when laboratory services are limited or unavailable. | |
| 3.2 | LABORATORY QUALITY MANAGEMENT SYSTEM (QMS) 3.2.1 All laboratories must develop detailed Standard Operating Procedures (SOPs) which should include all laboratory analytical and operational procedures according to the scope of services provided by the facility. 3.2.2 The SOPs must be documented using a step-by-step approach and all procedures must be subject to a quality monitoring process. |
3.2.5.7 Infection control and Environmental Health and safety management 3.2.5.8 Information Management 3.2.5.9 Customer service and Customer Focus improvement processes 3.2.5.10 Outsourcing Clinical Laboratory Services 3.2.5.11 Nonconforming Event Management 3.2.5.12 Facilities and Laboratory Safety 3.2.5.13 Waste management including an emergency contingency plan in case of a spill or exposure. 3.2.5.14 Management of samples, specimens and biological material including; 3.2.5.14.1 Specimen collection, labelling and transport 3.2.5.14.2 Specimen/sample receiving and processing (detailed test by test); 3.2.5.14.3 Specimen/sample handling, preparation and storage; 3.2.5.14.4 Sample retention and disposal; 3.2.5.14.5 Minimizing the risk of interchange of Samples and subsamples; 3.2.5.14.6 Minimizing risk to ensure the safety of the specimen, collector, carrier, the general public and the receiving Laboratory. 3.2.5.15 Tests and Results; 3.2.5.15.1 The methodology for performing the tests 3.2.5.15.2 Turnaround times 3.2.5.15.3 Results validation and reporting 3.2.5.15.4 Quality control limits for each test, reference ranges, and reportable ranges to ensure that when patient results are reported, they reflect actual normal and abnormal conditions. 3.2.5.16 Laboratory Decontamination 3.2.5.17 Nonconforming Event Management 3.2.5.17.1 Correction, and prevention of nonconforming events in all aspects of the quality management system including pre-examination, examination and post-examination processes. 3.2.5.18 Continual Improvement 3.2.5.19 Health safety and environment plan to ensure safety of the patients, staff and visitors
| 3.3 | HEALTH INFORMATION MANAGEMENT 3.3.1 Medical records must be kept confidential and comply with the requirements of the DHCC Health Data Protection Regulation No. 7 of 2008. Medical records may only be released in accordance with the provisions outlined in the DHCC Health Data Protection Regulation. 3.3.2 Licensed Laboratories must comply with the DHCC Medical Records Policy. 3.3.3 Medical records must contain the specific data elements required by the Healthcare Information Reporting and Analysis System (HIRAS) which are detailed in the DHCC Minimum Data Requirement Rule2008. 3.3.4 Records related to Patient testing must be kept for at least ten (10) years following the date of testing, or for such other time as may be required by the Licensing Board. Such records shall include, at a minimum, Test order, Test report, specimens, blocks, slides and all documentation created during the testing process. |
| 3.4 | PATIENT RIGHTS AND RESPONSIBILITIES 3.4.1 Each Healthcare Operator licensed to provide laboratory services shall provide patients and families with information regarding the DHCA Patients' Rights and Responsibilities in accordance to Schedule Two of the DHCA Governing. 3.4.2 Regulation Number (1) of 2013. This information shall be displayed in English and Arabic throughout the facility for patients and visitors to review Each Healthcare Operator providing laboratory services shall provide processes that support patients' and families' rights during care. 3.4.3 Informed Consent shall be obtained as applicable through a process defined by each Healthcare Operator providing laboratory services and carried out by trained staff in a manner and language the patient can understand in accordance with the DHCR Informed Consent Policy. 3.4.4 Legal guardians, in the case of minors or legally incompetent adult, shall be informed of and agree to the laboratory service provided. |
| 3.5.3 Each laboratory shall provide suitable infrastructure according to the services provided by the laboratory. The basic infrastructure shall include: 3.5.3.1 Reception room/area 3.5.3.2 Phlebotomy room 3.5.3.3 Specimen collection room/area, with nearby toilet 3.5.3.4 Laboratory Work/Testing area 3.5.3.5 Specimen/Sample/slide storage facility including cold storage where applicable 3.5.3.6 Area for the collection of medical waste, general storage for supplies and equipment in addition to a storing area/cabinet for hazardous materials 3.5.3.7 Autoclave and Sterilization Areas 3.5.3.8 Fume hoods 3.5.3.9 Biological safety cabinets 3.5.3.10 Eye wash station 3.5.3.11 Water supply suitable for analytical purposes 3.5.3.12 Adequate power supply 3.5.3.13 Adequate ventilation, climate control and lighting arrangements 3.5.3.14 Separate room/area for meetings/administrative work 3.5.3.15 Separate facilities/area for staff for eating and storing food, drinks etc. 3.5.3.16 Communication facility with referral centers 3.5.3.17 Additional infrastructure facilities may be added for special tasks | |
| 3.6 | QUALITY OVERSIGHT AND ACCREDITATION 3.6.1 Each licensed Healthcare Operator providing laboratory services shall be subject to this standard, the DHCR quality oversight policies, and other applicable DHCA regulations, standards and policies. 3.6.2 In addition to satisfying the other provisions of this standard, each licensed HCO offering clinical laboratory services is to obtain accreditation for the laboratory services from a DHCR approved accreditation organization as appropriate to its scope of laboratory services within one (1) year of commencing services in the laboratory and shall ensure maintaining accreditation for all its services all times throughout its operations. The following accreditation organizations are recognized and approved by DHCA to survey and award accreditation to laboratories in DHCC: 3.6.2.1 College of American Pathologists (CAP); 3.6.2.2 Accreditation Canada (CA); |
| 3.6.2.3 | Joint Commission International Accreditation, Standards for Laboratories (JCIA); |
| 3.6.2.4 | Accreditation against ISO 15189 Standards by other International; Laboratory Accreditation Cooperation (ILAC) registered accreditation organizations with prior approval of the Quality Council. (Examples include CPA - UK, NATA - Australia); |
| 4 | APPENDICES |
| 1 | Guidelines on Specific Services |
| 5 | DEFINITIONS |
| 5.1 | Accreditation: procedure by which an authoritative body gives formal recognition that an organization is competent to carry out specific tasks. |
| the diagnosis, management, prevention and treatment of disease in, or assessment of the health of, human beings, and which may provide a consultant advisory service covering all aspects of laboratory investigation including the interpretation of results and advice on further appropriate investigation. These examinations also include procedures for determining, measuring or otherwise describing the presence or absence of various substances or microorganisms. | |
| 5.10 | External Proficiency Test: The use of inter-laboratory comparisons to determine the performance of a laboratory with respect to individual test(s), measurement(s) or observation(s), and to monitor a laboratory's continuing performance. |
| 5.19 | Referral laboratory: A laboratory may often require the assistance of an outside facility or facilities to perform unique or unusual services, as a backup service, or for routine services that the referring (primary) laboratory does not perform. |
| 5.20 | Reference laboratory: Is an external laboratory in DHCC to which another laboratory management chooses to submit a sample or sub-sample for examination or when routine examinations cannot be carried out. It may also be a laboratory that performs reference or calibration measurement procedures or assigns reference values to test objects, later potentially providing those associated reference values for references or sources of traceability of test results. |
| 6.1 | International Standard ISO 15189,Third edition, 2012 |
| 6.2 | International Standard ISO 17000 |
1.1. DHCA licensed healthcare providers may apply for authorization to provide POCT services under their existing license either at the time of facility license renewal, or at any time prior to the due date for license renewal. For facilities that have DHCA license for its laboratory, this license will cover POCT applications. For non-licensed entities, applicants may include the provision of POCT services as part of their application for new facility license Provision of POCT will be authorized under the DHCA issued facility license; that is, no separate license will be issued for POCT services.
1.2. A Licensed Point of Care Testing Laboratory (POCT) must engage a different Licensed Laboratory to oversee and supervise the overall operation of the POCT Laboratory.
1.3. A POCT laboratory may perform...